一个用于从各个制造商控制池设备的应用程序。
Local, open-source control for Pentair IntelliCenter / IntelliTouch / EasyTouch, Jandy Aqualink, Hayward, and standalone pool equipment. A self-hosted alternative to the Pentair Home and ScreenLogic cloud apps — your data stays on your network, your pool responds in real time, and your smart home can finally see it.
UI pictured: dashPanel, the recommended web client.
Quick start (Docker): see Docker Compose — one file,
docker compose up -d, done. Quick start (source):git clone→npm install→npm start. Full steps in Installation. Hardware needed: an RS-485 adapter (or a ScreenLogic network connection) to talk to your equipment.
In the wild: featured in the TroubleFreePool IntelliCenter walk-through guide (thanks @MyAZPool). Actively maintained — questions welcome in GitHub Discussions.
+ NEW in 10.0: IntelliCenter WebSocket protocol — control your pool over
+ the local network with no RS-485 adapter. Just plug in Ethernet.
+ If anything looks off, please open a discussion with a replay capture.njsPC is a Node.js service that talks to your pool controller over RS-485 (or ScreenLogic) and exposes everything — circuits, bodies, pumps, heaters, chlorinators, chemistry, lights, covers, valves, schedules — as a live REST + WebSocket API. Point a web client at it for a browser UI, or wire it into home automation so your pool shows up next to your lights and thermostats.
| Category | Supported | Notes |
|---|---|---|
| Controllers | IntelliCenter, IntelliTouch, EasyTouch, SunTouch, Aqualink, IntelliCom, Nixie (standalone) | RS-485, ScreenLogic (network), or IntelliCenter local WebSocket (new in 10.0 — no adapter needed) |
| Pumps | IntelliFlo VS / VSF / VF, IntelliFlo VS+SVRS, SuperFlo VS, Hayward Eco/TriStar VS, Hayward Relay VS, Whisperflo, single/two-speed, relay-controlled, Neptune Modbus, Regal (Century) Modbus | Regal added in 9.0 — PR #1169 |
| Heaters | Gas, solar, heat pump, hybrid (ETi / ETi250), MasterTemp, Max-E-Therm, UltraTemp / UltraTempDirect, Jandy JXi / LXi | JXi/LXi added in 9.1 — discussion #1128 |
| Chlorinators | IntelliChlor, Aqua-Rite, OEM brands (physical and virtual) | Dual chlorinators supported via REM. Virtual chlorinator added in 9.1 |
| Lights | IntelliBrite, MagicStream, Jandy WaterColors, Hayward ColorLogic, Pooltone (Florida Sunseeker), plus legacy SAM / SAL / Color Wheel / Photon Gen | |
| Chemistry | IntelliChem (OCP-paired, standalone, and virtual), Relay Equipment Manager (REM) | Atlas Scientific pH / ORP / EC probes, flow, pressure, temperature via REM. Virtual IntelliChem added in 9.1 |
| Covers | IntelliCenter cover configuration & control | Live-state feedback is limited on ICv3 |
| Filters | Configuration, pressure monitoring, clean/dirty thresholds | |
| Valves | Standard intake/return with diverted status | Intellivalve planned |
| Home Automation | HomeKit/Siri (Homebridge), Home Assistant (via MQTT), Hubitat, SmartThings, MQTT, InfluxDB, ISY, Vera, Alexa | See Home Automation Bindings |
IntelliCenter WebSocket Protocol — Communicate Without RS-485 Hardware.
For the first time, njsPC can talk to IntelliCenter v3.004+ controllers over the local network using Pentair's native JSON WebSocket protocol on port 6680. No RS-485 adapter, no serial wiring — just Ethernet. This is a complete alternative communication path with full bidirectional config, live state push, and equipment control.
ocpws with mDNS auto-discovery, JSON request/response protocol, and live NotifyList push subscriptions. Selectable from dashPanel alongside all existing transport types.GetParamList queries over WebSocket.SetParamList writes. Real-time state changes received via subscriptions.IntelliCenterV1Board (RS-485 v1.x), IntelliCenterWSBoard (WebSocket mode), and shared base. Board swaps dynamically at runtime when you change transport type.See the full Changelog for all 33 items in 10.0.
What was new in 9.1
9.1 adds IntelliCenter security, Jandy JXi/LXi heater support, virtual chemistry equipment, and a batch of v3.008 refinements.
/config/alerts endpoint for all 7 alert categories with dashPanel accordion UI and ICP→dashPanel real-time sync.What was new in 9.0
9.0 focused on IntelliCenter v3.008 firmware compatibility and finished the v3 work started in 8.4.1.
For earlier releases (8.4.x, 8.3, 8.1, 8.0, 7.x and before), see the Changelog.
Before you start — hardware required njsPC needs a way to reach your pool bus:
- RS-485 adapter (recommended) — see the adapter details wiki.
- ScreenLogic (network connection) — if you already have a Pentair ScreenLogic box on your network.
- IntelliCenter v3 local WebSocket (network connection, no adapter) — see Local Network Comms (IntelliCenter v3) below.
- Socat — to bridge a remote serial device, see the Socat wiki.
IntelliCenter v3.004+ exposes a JSON WebSocket API on port 6680 of the OCP. njsPC can use this as an alternative to RS-485 — no adapter, no wiring. Configure it from the dashPanel comms page by selecting port type IntelliCenter Network, hitting Discover to mDNS-browse the LAN, and Save.
Prerequisites
How it works
Pentair -i -n advertised under _http._tcp.local. The Discover button calls GET /config/options/ocpws/search.GetParamList objnam:"ALL" to enumerate the panel and a RequestParamList to subscribe for live NotifyList push updates.暂无开放 Issues,或尚未同步最近议题。