Watermeter ZigBee TLSR8258
The project uses a module from E-BYTE on the TLSR8258F512ET32 chip, the E180-Z5812SP.
Everything was tested on this dongle from Telink
The case is made on a 3D printer.
Module Schematic.
The leakage sensor itself consists of two contacts. When the contacts are immersed in water, the resistance between them changes. This is what the device detects.
It is possible to buy ready-made ones, for example from the company Gidrolock - Gidrolock WSP.
Or on Aliexpress these
Or solder two wires to two pins of, for example, a pin header connector. The result will be the same :)
The latest firmware must be injected into the module using github.com/pvvx/TLSRPGM or the original Telink programmer.
You can read here how to make an inexpensive programmer based on TB-03 or TB-04 modules.
The project is shaped in such a way that it can be built with regular make on Windows, in the Git Bash shell, as well as on Linux (I tested on Debian 11).
You can read how to add a project to Eclipse here. Everything is exactly the same, but for a different project.
The firmware is built according to the schematic, i.e. the board file board_8258_diy.h is connected. The dongle board is also adapted, i.e. board_8258_dongle.h. For other variants you will have to edit the file of the required board yourself.
At the first startup, an attempt is made to connect to the Zigbee network. If the attempt is successful, the module enters the normal operating mode.
Polling For the first 30 seconds, the module wakes up every 3 seconds. After 30 seconds, the module goes to sleep for 5 minutes. After 5 minutes, it wakes up again once every 3 seconds for the next 30 seconds. Then it goes back to sleep for 5 minutes. And so on in a circle. You could make the module wake up once every 5 minutes, but zigbee2mqtt by default checks for devices on the network about once every 10 minutes. And it starts swearing in the log that the device is not found and sets the status offline. With such an uneven scheme this problem is eliminated. This of course can be configured in zigbee2mqtt, but I preferred this option. Making the wake-up period always once every 3 seconds is an unreasonable waste of battery life.
Reporting
The module sends four different reports. Two for the battery and two more for the cold and hot water meter. They have different sending periods.
The module checks the battery voltage once every 15 minutes. Reports on battery status (voltage in mV and remaining life in %) are sent not earlier than 5 minutes from the previous one (if there were changes), but not later than 1 hour (even if there were no changes).
The report of the water meter value is sent immediately when the value increases. And no later than 5 minutes from the previous report. If 5 minutes seems too frequent to someone, this can always be corrected via the zigbee2mqtt web interface in the Reporting section.
Reports are also forcibly sent within 5 seconds by pressing the instrument button.
The code used in Telink's examples for reporting is a bit (I would even say a lot!) crooked. It prevents the module from falling asleep for more than 1 second. And if it is not critical for devices that are powered from stationary sources, it is already a disaster for battery-powered devices. That's why the original reporting aglorithm was replaced by a custom one, which is based on starting timers by MinInterval and MaxInterval, which allowed the module to fall asleep exactly for these intervals, and not for 1 second, as it was before.
LED indication of module modes
If the module does not blink the LED for a long time (more than 5 minutes), it is in the deep sleep mode. The module can exit this mode in two cases. First - if the user presses the button. The second - if the reed switch in any water meter is triggered (closed or open).
Module memory and where the config is stored
According to the TLSR8258F512ET32 chip specification, the memory is distributed as follows
0x00000 Old Firmware bin 0x34000 NV_1 0x40000 OTA New bin storage Area 0x76000 MAC address 0x77000 C_Cfg_Info 0x78000 U_Cfg_Info 0x7A000 NV_2 0x80000 End Flash
It turns out that the firmware can't be bigger than 0x34000 (which is actually confirmed by checking the SDK to determine the size of the uploaded file when updating OTA), but when using the firmware from address 0x40000, you can see that 0x36000, not 0x34000, is allocated for it. It appears that 0x2000 is never used. This is what we will use to store the intermediate config. The intermediate config is written to NV_2 (somewhere in the area from 0x7a000 to 0x7c000). The NV_MODULE_APP module with the number NV_ITEM_APP_USER_CFG is used (for understanding see app_cfg.h and sdk/proj/drivers/drv_nv.h).
After the hardware firmware is injected into the module, it always starts from address 0x00000. After OTA update, the start address changes. If before the update it was 0x00000, after the update it becomes 0x40000. If before the update it was 0x40000, after it becomes 0x00000. And so on in a circle after each OTA update.
At the moment of module startup we check whether the firmware is loaded from address 0x00000 or 0x40000. If it is loaded from address 0x00000, we use the area from 0x40000 to 0x74000 to store the config. If the firmware is loaded from address 0x40000, we use the area from 0x00000 to 0x34000 to store the config.
Examples of device log output after OTA update
OTA update successful. OTA mode enabled. MCU boot from address: 0x40000 Save restored config to nv_ram in module NV_MODULE_APP (6) item NV_ITEM_APP_USER_CFG (45)
OTA update successful. OTA mode enabled. MCU boot from address: 0x0 Save restored config to nv_ram in module NV_MODULE_APP (6) item NV_ITEM_APP_USER_CFG (45)
The config is written to the selected area each time the water meter is triggered in 0x100 increments. I.e. the first time the config is written to address 0x40000 (0x00000), the second time 0x40100 (0x00100), the third time - 0x40200 (0x00200) and so on until it reaches the boundary 0x74000 (0x34000). And then it starts writing again from the initial address 0x40000 (0x00000).
Save config to flash address - 0x0 cold counter - 2010 Save config to flash address - 0x100 cold counter - 2020 Save config to flash address - 0x200 cold counter - 2030 Save config to flash address - 0x300 cold counter - 2040 Save config to flash address - 0x400
Save config to flash address - 0x40000 cold counter - 2090 Save config to flash address - 0x40100 cold counter - 2100 Save config to flash address - 0x40200 cold counter - 2110 Save config to flash address - 0x40300 cold counter - 2120 Save config to flash address - 0x40400 At the moment of OTA update the config is saved in nv_ram. It will remain there until the OTA update is successfully completed.
After successful completion of the OTA update, the module reboots, reads the config from nv_ram, checks at which address the config should be written in normal mode and saves it at address 0x00000 or 0x40000. And so on until the next update.
Leak detectors
When a leak is detected (i.e. the contacts of any leak sensor are immersed in water), the state of the IAS cluster changes and two On commands are sent immediately to the On_Off clusters at Endpoints 4 and 5. When the water dries, the state of the IAS cluster changes and no commands are sent to the On_Off cluster.
Both On_Off clusters should directly "bind" to the executable (enforced in the zigbee2mqtt web-interface in the bind device section). What it gives. Even if the network goes down, when for example the coordinator is not working, Watermeter will still send the selected On (off or toggle) command directly to the actuator and everything will work (we understand that the actuator must have a duplicate autonomous power supply!). Binding both channels to the same device is not recommended.
Zigbee Claster and Attribute
The firmware uses 5 endpoints, that's like 5 different logical devices on one physical device. What for. The Zigbee standard does not allow using the same clusters with the same attributes on the same endpoint. And we have two identical counters with the same CurrentSummationDelivered attributes in the SeMetering cluster. And two identical On_Off clusters. So the first enpoint has the hot water meter, the second has the cold water meter, the third has the settings, the fourth has the IAS and the first On_Off, and the fifth has the second On_Off.