Out of Memory crashes in Sub-Ghz

Author: LechnioCreated Jul 11, 2026Updated Jul 16, 2026
Labelsneeds-triagesubghz

Describe the bug.

There are multiple cases where Sub-Ghz crashes with OOM even right after reboot with fresh RAM.

I link this issue as my OOM tests started there. But I create this on as an another tracker.

All reproduced on HEAD-8ed809.

Reproduction

For example that one (regression since mntm-012)

  1. Open subghz, go to [Read] for a sec (no need to catch anything)
  2. Go to [Saved], chose any RAW file (short, long doesnt metter)
  3. Try to [Send] this RAW - OOM crash

Crash2:

  1. Open any RAW file and try to send it - crash

Crash3:

  1. Open any RAW file and try to decode - crash

Crash4:

  1. Open subghz app, send couple keeloqs from saved file.
  2. Exit subghz app by pressing back few times - crash.

Crash5:

  1. connect to PC via USB, open qFlipper.
  2. open Subghz app - rangom crash
  3. If not crashe in pkt2 go to [Saved] few times - OOM again

Reboot, powerof, nothing helps, insta crash on latest 8ed809 dev.

This information is outdated: https://github.com/Next-Flip/Momentum-Firmware/issues/555#issuecomment-4657342682 Max I can record after fresh reboot without USB is 17 signals and 9 with USB connected.

Target

No response

Logs

No logs yet. In my spare time I will add some profiling to rewrite this but seems like there are few issues that come from unleashed firmware (at least one I already found came in 67e191b1)

Anything else?

No response