Modbus framework for Rust
rmodbus - Modbus for Rust
A framework to build fast and reliable Modbus-powered applications.
rmodbus is not a yet another Modbus client/server. rmodbus is a set of tools to quickly build Modbus-powered applications. Consider rmodbus is a request/response codec, plus context manager.
rmodbus is a part of EVA ICS v4 industrial automation stack and RoboPLC I/O.
no_std is fully supported!)Yes, there is no server included. You build the server by your own. You choose the transport protocol, technology and everything else. rmodbus just process frames and works with Modbus context.
For synchronous servers and clients (std) we recommend using RoboPLC Modbus I/O modules.
Here is an example of a simple TCP blocking server:
…There are also examples for Serial-RTU, Serial-ASCII and UDP in examples folder (if you're reading this text somewhere else, visit rmodbus project repository.
Launch the examples as:
cargo run --example app
cargo run --example tcpserverThe rule is simple: one standard Modbus context per application. 10k+10k 16-bit registers and 10k+10k coils are usually more than enough. This takes about 59Kbytes of RAM.
rmodbus server context is thread-safe, easy to use and has a lot of functions.
The context must be protected with a mutex/rwlock and every time Modbus context is accessed, a context mutex must be locked. This slows down performance, but guarantees that the context always has valid data after bulk-sets and after writes of long data types. So make sure your application locks context only when required and only for a short period time.
A simple PLC example:
…To let the above program communicate with outer world, Modbus server must be up and running in the separate thread, asynchronously or whatever is preferred.
no_stdrmodbus supports no_std mode. Most of the library code is written the way to
support both std and no_std.
For no_std, set the dependency as:
rmodbus = { version = "*", default-features = false }The full Modbus storage has 10000 registers of each type, which requires 60000 bytes total. For systems with small RAM amount there is a pre-defined small storage with 1000 registers:
use rmodbus::server::{storage::ModbusStorageSmall, context::ModbusContext};Starting from the version 0.7 it is allowed to define storage of any size using generic constants. The generic constants order is: coils, discretes, inputs, holdings.
E.g. let us define a context for 128 coils, 16 discretes, 0 inputs and 100 holdings:
use rmodbus::server::{storage::ModbusStorage, context::ModbusContext};
let context = ModbusStorage::::new();Starting from the version 0.9 it is allowed to provide custom server implementation
by implementing use rmodbus::server::context::ModbusContext on custom struct.
For sample implementation have a look at src/server/storage.rs
u16 sized registersStarting from version , you can implement
server::RegisterRepresentable on your own types and use
ModbusContext::set_*_as_representable and ModbusContext::get_*_as_representable
methods to directly store and read your own types in the registers.
Some of rmodbus functions use vectors to store result. Different vector types can be used:
When the std feature is enabled (default), std::vec::Vec can be used.
With the fixedvec feature, fixedvec::FixedVec can be used.
With the heapless feature, heapless::Vec can be used.
When the alloc feature is enabled, Rust core allocation alloc::vec::Vec
can be used in no-std mode. E.g cargo build --no-default-features --features alloc builds in no-std mode, and supports using core allocation
alloc::vec::Vec. When std feature is enabled, the alloc feature is
ignored.
Modbus client is designed with the same principles as the server: the crate gives frame generator / processor, while the frames can be read / written with any source and with any required way.
TCP client Example:
…Bohemia Automation / Altertech is a group of companies with 15+ years of experience in the enterprise automation and industrial IoT. Our setups include power plants, factories and urban infrastructure. Largest of them have 1M+ sensors and controlled devices and the bar raises higher and higher every day.
No open issues yet, or sync has not completed.